Our products are widely used in thermal power, nuclear power, aerospace, chemical, transportation, rail, ships, and heavy equipment both domestically and internationally. Our company's independent core technology is China's first acid free clean armored cable production line
Keywords: Thermocouple, Thermal resistance
Product Details
9.1 Boiler metal wall temperature armored thermocouples
Armored thermocouple with collector block as the temperature measuring element is used to measure the temperature of screen over, high over, high again and other metal pipe wall.
Technical Reference Sheet
|
Thermocouple graduation number |
Temperature measuring element |
Diameter size |
Operating temperature |
Sheath material |
Armor Length |
lead wire |
Insulation resistance value |
|
K or E |
Recommended double |
Φ3 or Φ4 |
0~600°C |
1Cr18Ni9Ti or 316 |
Maximum length<120m |
Recommend 2m |
>1000MΩ/500VDC at 20°C >5MΩ/500VDC at 500°C *At 660°C, >5MΩ/500VDC |
|
Recommended Φ5 or Φ6 |
0~800°C |
||||||
|
1) The insulating layer of the armored thermocouple has limited conductivity, and the insulation resistance value decreases with the increase of the length of the armored thermocouple, so the electrical conductivity of the armored thermocouple is represented by Sm-1 (equal to Ω -1 m - 1 ), so the minimum insulation resistance of armored thermocouples with a length greater than 1m is represented by Ωm or MΩm, and those less than 1m are represented by MΩ;
|
|||||||
Name: armored thermocouple with compensation wire Name: junction box armored thermocouple